Low voltage LED lamps are dependent on the transformer system in which they are installed so it is misleading to state that low voltage LED lamps are dimmable or not dimmable. Typically low voltage LED lamps work very well on magnetic transformer systems but can have problems with dimming on electronic transformer systems. We strongly encourage testing low voltage LED lamps in your current system for compatibility.
MR16 Dimmers & Transformers Compatibility
This MR16 12V led bulb could be used for both systems with a dimmer and without dimmers. Below is the compatible list of transformers for systems WITHOUT a dimmer; as well as transformer and dimmer compatibility List – for systems WITH a dimmer .
1) For Systems WITHOUT a dimmer
Brand | Tranformer Model | Input Voltage(VAC/Hz) | Wattage(W) | Type | MR16s per Transformer(no dimmer connected) | |||||
1 | 2 | 3 | 4 | 5 | 6 | |||||
Advance | 71A9743 | 120VAC, 60Hz | 75 | MT | G | G | G | G | G | G |
HUA1200600X2L | 120VAC, 60Hz | 60 | ET | G | G | G | G | G | G | |
250LED100W | 120VAC, 60Hz | 100 | ET | G | G | G | G | G | G | |
250LED10W | 120VAC, 60Hz | 10 | ET | G | N/A | N/A | N/A | N/A | N/A | |
250AT075T | 120VAC, 60Hz | 75 | MT | G | G | G | G | G | G | |
Hatch | RS12-15M-LED | 120VAC, 50-60Hz | 15 | ET | F | F | G | N/A | N/A | N/A |
PS12-20L | 120VAC, 60Hz | 20 | ET | G | G | G | G | N/A | N/A | |
RS12-30M-LED | 120VAC, 50-60Hz | 30 | ET | G | G | G | G | G | G | |
RS12-60M | 120VAC, 50-60Hz | 60 | ET | G | G | G | G | G | G | |
VS12-60W | 120VAC, 50-60Hz | 60 | ET | G | G | G | G | G | G | |
VS12-60WD | 120VAC, 50-60Hz | 60 | ET | G | G | G | G | F | G | |
RS12-80M | 120VAC, 50-60Hz | 80 | ET | G | G | G | G | G | G | |
RS12-60M-LED | 120VAC, 50-60Hz | 60 | ET | G | G | G | G | G | G | |
LCI | i60e | 230VAC,50-60Hz | 60 | ET | G | G | G | G | G | G |
Lighttech | LET-60*** | 120VAC, 50-60Hz | 60 | ET | F | F | F | F | F | F |
LET-75*** | 120VAC, 50-60Hz | 75 | ET | F | F | F | F | F | F | |
Ligo | E12SC50SA | 230VAC | 50 | MT | G | G | G | G | G | G |
Lumex | MTR50/12EN-61558 | 220VAC, 50Hz | 50 | MT | G | G | G | G | G | G |
MDL | 319-0103 | 120VAC, 50-60Hz | 10 | ET | G | N/A | N/A | N/A | N/A | N/A |
Mirano | BLNET-L50C 50W | 220VAC, 50Hz | 50 | ET | G | G | G | G | G | G |
Niko | 320-00112 | 230VAC, 50Hz | 105 | ET | G | G | G | G | G | G |
Nobile | EN-60D*** | 230VAC,50-60Hz | 60 | ET | G | F | F | F | F | F |
EN60D2*** | 230VAC,50-60Hz | 60 | ET | F | F | G | F | F | F | |
EN-70D*** | 230VAC,50-60Hz | 70 | ET | F | F | F | G | G | G | |
EN-80D | 230VAC,50-60Hz | 80 | ET | G | G | G | G | G | G | |
EN-80D2*** | 230VAC,50-60Hz | 80 | ET | G | G | G | G | F | F | |
EN-110D | 230VAC,50-60Hz | 110 | ET | G | G | G | G | G | G | |
EN-110D*** | 230VAC, 50Hz | 110 | ET | F | F | F | F | F | F | |
OSRAM | HTM 150/230-240 | 230VAC,50-60Hz | 150 | ET | G | G | G | G | G | G |
Phillips | Primaline 105 230-240 | 230-240VAC,50-60Hz | 105 | ET | G | G | G | G | G | G |
Xitanium 10W Dimmable | 220-240VAC,50-60Hz | 10 | ET | G | N/A | N/A | N/A | N/A | N/A | |
Sunrise | H0050-497 | 120VAC,50-60Hz | 50 | MT | G | G | G | G | G | G |
Tridonic | VIPER 22176074*** | 230V-240VAC,50-60Hz | 105 | ET | G | F | G | F | G | F |
VIPER 22176072*** | 230V-240VAC,50-60Hz | 105 | ET | G | G | F | F | F | F | |
VadsBO | SET70RE-1 | 220-240AC,50Hz | 70 | ET | G | G | G | G | G | G |
Vossloh Schwabe | EST 70/12.380 | 230V-240VAC,50-60Hz | 70 | ET | G | G | G | G | G | G |
EST 105/12.381 | 230V-240VAC,50-60Hz | 105 | ET | G | G | G | G | G | G | |
EST 150/12.622 | 230V-240VAC,50-60Hz | 150 | ET | G | G | G | G | G | G | |
WAC | EN-12100-R-AR | 120VAC,50-60Hz | 100 | ET | G | G | G | G | G | G |
Wang | WH-601E2CA-2L | 120VAC,60Hz | 60 | ET | G | G | G | G | G | G |
*** Not recommended for use with dimmer. | ||||||||||
Symbol / Description | ET /Electronic Tranformer | MT /Magnetic Transformer | F /Flickers | |||||||
N/A /Exceeds Transformer | G /Good Recommended Power |
1) For Systems WITH dimmer
Brand | Tranformer Model | Input Voltage(VAC/Hz) | Power Rating (W) | Type | Number of MR16s per Transformer on a low voltage Dimmer Percent Dimming Range | |||||
1 | 2 | 3 | 4 | 5 | 6 | |||||
Advance | 71A9743 | 120VAC, 60Hz | 75 | MT | 10-100% | 10-100% | 10-100% | 10-100% | 10-100% | 10-100% |
CHD | HUA1200600K2L | 120VAC, 60Hz | 60 | ET | 60-100% | 60-100% | F | 60-100% | 60-100% | 60-100% |
ELG | 250LED100W | 120VAC, 60Hz | 100 | ET | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
250LED10W | 120VAC, 60Hz | 10 | ET | 0-100% | N/A | N/A | N/A | N/A | N/A | |
250AT075T | 120VAC, 60Hz | 75 | MT | 10-100% | 10-100% | 10-100% | 10-100% | 10-100% | 10-100% | |
Hatch | RS12-15M-LED | 120VAC, 50-60Hz | 15 | ET | 0-100% | 0-100% | N/A | N/A | N/A | N/A |
PS12-20L | 120VAC, 60Hz | 20 | ET | 20-100% | 20-100% | 20-100% | N/A | N/A | N/A | |
RS12-30M-LED | 120VAC, 50-60Hz | 30 | ET | 0-100% | 0-100% | 0-100% | 0-100% | N/A | N/A | |
RS12-60M | 120VAC, 50-60Hz | 60 | ET | 10-100% | 10-100% | 10-100% | 10-100% | 10-100% | 10-100% | |
VS12-60W | 120VAC, 50-60Hz | 60 | ET | 20-100% | 20-100% | 20-100% | 20-100% | 20-100% | 20-100% | |
VS12-60WD | 120VAC, 50-60Hz | 60 | ET | 30-100% | 30-100% | 30-100% | 30-100% | 30-100% | 30-100% | |
RS12-80M | 120VAC, 50-60Hz | 80 | ET | 10-100% | 10-100% | 10-100% | 10-100% | 10-100% | 10-100% | |
RS12-60M-LED | 120VAC, 50-60Hz | 60 | ET | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | |
LCI | i60e*** | 230VAC,50-60Hz | 60 | ET | F | F | F | F | F | F |
Lighttech | LET-60*** | 120VAC, 50-60Hz | 60 | ET | F | F | F | F | F | F |
LET-75*** | 120VAC, 50-60Hz | 75 | ET | F | F | F | F | F | F | |
Ligo | E12SC50SA | 230VAC | 50 | MT | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
Lumex | MTR50/12EN-61558 | 220VAC, 50Hz | 50 | MT | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
MDL | 319-0103*** | 120VAC, 50-60Hz | 10 | ET | 0-100% | F | F | F | F | F |
Mirano | BLNET-L50C 50W | 220VAC, 50Hz | 50 | ET | 0-50% | 0-50% | 0-50% | 0-60% | 0-60% | 0-60% |
Niko | 320-00112*** | 230VAC, 50Hz | 105 | ET | 0-60% | 0-60% | F | F | F | F |
Nobile | EN-60D*** | 230VAC,50-60Hz | 60 | ET | F | F | F | F | F | F |
EN60D2*** | 230VAC,50-60Hz | 60 | ET | F | F | F | F | F | F | |
EN-70D*** | 230VAC,50-60Hz | 70 | ET | F | F | F | F | F | F | |
EN-80D | 230VAC,50-60Hz | 80 | ET | 0-50% | 0-50% | 0-60% | 0-70% | 0-70% | 0-70% | |
EN-80D2*** | 230VAC,50-60Hz | 80 | ET | F | F | F | F | F | F | |
EN-110D | 230VAC,50-60Hz | 110 | ET | 30-70% | 30-70% | 30-70% | 30-70% | 30-70% | 20-70% | |
EN-110D*** | 230VAC, 50Hz | 110 | ET | F | F | F | F | F | F | |
OSRAM | HTM 150/230-240 | 230VAC,50-60Hz | 150 | ET | 30-70% | 30-70% | 30-70% | 30-70% | 30-70% | 30-70% |
Phillips | Primaline 105 230-240 | 230-240VAC,50-60Hz | 105 | ET | 0-80% | 0-80% | 0-80% | F | F | F |
Ntanium 10W Dimmable | 220-240VAC,50-60Hz | 10 | ET | 0-100% | N/A | N/A | N/A | N/A | N/A | |
Sunrise | H0050-497 | 120VAC,50-60Hz | 50 | MT | 20-100% | 20-100% | 20-100% | 20-100% | 20-100% | 20-100% |
Tridonic | VIPER 22176074*** | 230V-240VAC,50-60Hz | 105 | ET | F | F | F | F | F | F |
VIPER 22176072*** | 230V-240VAC,50-60Hz | 105 | ET | F | F | F | F | F | F | |
VadsBO | SET70RE-1 | 220-240AC,50Hz | 70 | ET | F | F | F | 30-70% | 30-70% | 30-70% |
Vossloh Schwabe | EST 70/12.380*** | 230V-240VAC,50-60Hz | 70 | ET | F | F | F | F | F | F |
EST 105/12.381*** | 230V-240VAC,50-60Hz | 105 | ET | F | F | F | F | F | F | |
EST 150/12.622*** | 230V-240VAC,50-60Hz | 150 | ET | F | F | F | F | F | F | |
WAC | EN-12100-R-AR | 120VAC,50-60Hz | 100 | ET | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
Wang | WH-601E2CA-2L | 120VAC,60Hz | 60 | ET | F | F | 20-100% | 20-100% | 20-100% | 20-100% |
*** Not recommended for use with dimmer. | ||||||||||
Symbol / Description | ET /Electronic Tranformer | MT /Magnetic Transformer | ||||||||
F /Flickers | N/A /Exceeds Transformer Recommended Power | |||||||||
120V magnetic transformers tested using Lutron DVLV-600P dimmers | ||||||||||
230V magnetic transformers tested using Lutron NTLV-600-277 dimmers | ||||||||||
120V magnetic transformers tested using Lutron SELVB-300P dimmers | ||||||||||
230V magnetic transformers tested using Lutron Everfourish EF0700DC dimmers |